OPTI is a world leading supplier of inverter systems with a wide international presence and a reputation for quality and technology. Their extensive experience and expertise in power protection make OPTI inverters the ideal solution to all power and solar applications.
OPTI Solar Inverters: An all-in-one solution for all solar system applications. Delivering true sinewave power output, the chargers feature a built in 50Amps solar charge controller and automatic charging of all battery types without risk of overcharge. Suitable for all kinds of loads, the compact modular design simplifies installation and provides the highest level of operating performance.
Features:
- Compatible with both inductive and resistive loads
- High output charger suitable for battery loads of 600AH
- Programmable operating settings
- Designed for continuous operation
- LCD multi-function status display with audible warnings
- Stylish housing and suitable for wall mounting
- High efficiency design
- Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat
SP 1200
Model | SP 1200 |
---|---|
Output Power | 1200VA/800W |
DC Input Voltage (Nominal/Range) | 12VDC (10VDC-16VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 40 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >75% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 16 |
Dimensions (mm) | H298, W150, D400 |
SP 2400
Model | SP 2400 |
---|---|
Output Power | 2400VA/1600W |
DC Input Voltage (Nominal/Range) | 24VDC (20VDC-32VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 50 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >80% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 24 |
Dimensions (mm) | H298, W190, D450 |
SP 3600
Model | SP 3600 |
---|---|
Output Power | 3600VA/2400W |
DC Input Voltage (Nominal/Range) | 24VDC (20VDC-32VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 50 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >80% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 26 |
Dimensions (mm) | H298, W190, D450 |
SP 5000
Model | SP 5000 |
---|---|
Output Power | 5000VA/4000W |
DC Input Voltage (Nominal/Range) | 24VDC (20VDC-32VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 60 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >80% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 26 |
Dimensions (mm) | H415, W260, D600 |
SP 6000
Model | SP 6000 |
---|---|
Output Power | 6000VA/6000W |
DC Input Voltage (Nominal/Range) | 48VDC (40VDC-64VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 60 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >80% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 52 |
Dimensions (mm) | H415, W260, D600 |
SP 8000
Model | SP 8000 |
---|---|
Output Power | 8000VA/8000W |
DC Input Voltage (Nominal/Range) | 48VDC (40VDC-64VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 60 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >80% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 54 |
Dimensions (mm) | H415, W260, D600 |
SP 11000
Model | SP 8000 |
---|---|
Output Power | 11000VA/11000W |
DC Input Voltage (Nominal/Range) | 48VDC (40VDC-64VDC) |
AC Output Voltage / Frequency (Nominal) | 240VAC / 50Hz |
Output Waveform | Pure Sinewave |
Maximum Charching Current (A) | 85 |
Audible Alarm | Alarm on Battery: low battery & battery over voltage. Alarm on abnormal operation : Overload, Short-circuit & Overheat |
Efficiency Nomal Mode | >75% |
Transfer Time | <8ms |
Over Current Protection | Circuit Breaker |
Control Panel | LCD or LED |
Weight (kg) | 95 |
Dimensions (mm) | H452, W277, D670 |